Sign In | Join Free | My xuijs.com |
|
Brand Name : KANGWEI
Model Number : According to the design and technical demand
Certification : CCS,BV
Place of Origin : WUXI , CHINA
MOQ : 1
Price : negotiated
Payment Terms : T/T, L/C
Supply Ability : 150SETS
Delivery Time : Negotiate
Packaging Details : CONTAINER ,WOODEN CASE
Main Materials : stainless steel
Application : HFO MDO power plant
Control : electrical box by PLC
voltage : 230,380,440,460
Capacity : 1000-10000L/H
Discharging Type : Variable Discharging
Motor Power : as the designed
heating source : steam exchanger or electrical
Various piping systems, provided for bunkering, storage, transfer, offloading and treatment of fuel oils. The following systems are provided for diesel engines that operate on heavy fuel oils: Fuel oil transfer system, Fuel oil treatment system and Fuel oil supply system.
- Fuel oil transfer system – This system receives and stores fuel and delivers it to settling tanks. Fuel oils are loaded through deck fill connections that have sample connections provided to permit the fuel to be sampled as it is taken aboard. HFO is loaded in storage tanks fitted with heating coils. In preparation for use, HFO is transferred to the fuel oil settling tanks via FO transfer pumps which are equipped with a suction strainer. Piping is so arranged that the pumps can transfer fuel between storage tanks and then to the deck connections for offloading. Settling tanks are used to permit gross water and solids to settle on the bottom.
- Fuel oil treatment system – From the settling tanks fuel oil is transferred to the service tanks via FO treatment system. For cleaning of heavy fuel oils (HFO) the two stage process is commonly used. The fuel is heated in a settling tank to about 50-60°C and then is drawn out by the purifier inlet pump. The inlet pump delivers the fuel to a thermostaticallycontrolled heater which raises the fuel temperature to about 80°C, and thence to the centrifugal purifier. The dry purified fuel is then transferred to a centrifugalclarifier by the purifier discharge pump. After clarification the clarifier discharge pump delivers the fuel to the service tank for the engine use.
Fuel oil supply module
- Fuel oil supply system – This system supplies the fuel from the service tank to the diesel engine. The system consists of: a supply flow meter, supply pumps, circulating pumps, preheaters, the final filter, a viscosity controller, a FO venting box.
The pressurised system is preferable while operating the diesel engine on high viscosity fuels. It can be delivered as a modular unit (fuel oil supply module), tested and ready for service supply connections.
Separator unit model parameters | |||||||
Model | SM203-S(O) | SS(A)203-S(O) | SS(A)204-S(O) | SS(A)405-S(O) | SS(A)309-S(O) | DS(A)203-S(O) | |
Item | |||||||
Separated volume | Rated value | 2000 | 1500 | 2000 | 3000 | 6000 | 1500 |
(L/H) | 0# Diesel oil | 2200 | 1600 | 2200 | 3500 | 6500 | 1600 |
30# SAE LO. | 1200 | 800 | 1200 | 1800 | 3600 | 800 | |
180Cst/50℃HFO | / | 700 | 1100 | 1600 | 3500 | 700 | |
Power(KW) | Separator | 2.2 | 1.5 | 3 | 5.5 | 11 | 1.5x2 |
Oil feed pump | 1.5 | 1.5 | 1.5 | 1.5 | 2.2 | 1.5(1.5x2) | |
E-heating | / | / | / | / | / | / | |
Others | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Slag discharge way | Manual Discharge | Auto slge / Auto partial discharge | |||||
Heating way | Steam 0.45~0.7MPa / Conduction oil 170~210℃ | ||||||
Control way | Relay | Relay / by PLC auto control | |||||
Machine weight | 780 | 760 | 785 | 980 | 1830 | 1300 | |
Outline dimension(mm) | Length | 1150 | 1150 | 1150 | 1300 | 1700 | 2000(2200) |
Width | 1150 | 1150 | 1150 | 1300/ | 1850 | 1200 | |
Height | 1700 | 1700 | 1700 | 1780 | 2070 | 1700 | |
Interface dimension | Fuel oil inlet/ | DN25/ | DN25/ | DN25/ | DN40/ | DN40/ | DN25/ |
outlet/ | DN25/ | DN20/ | DN25/ | DN32/ | DN40/ | DN25/ | |
return oil outlet | DN25 | DN20 | DN25 | DN32 | DN40 | DN25 | |
Medium inlet | DN20(DN25) | DN20(DN25) | DN20(DN25) | DN25 | DN25 | DN20(DN25) | |
Medium outlet | DN20(DN25) | DN20(DN25) | DN20(DN25) | DN20(DN25) | DN25 | DN20(DN25) | |
Control water inlet | G1/2” | G1/2” | G1/2” | G1/2” | G1/2” | G1/2” | |
Incoming cable | CEFR4x2.5 | CEFR4x2.5 | CEFR4x2.5 | CEFR4x4 | CEFR4x6 | CEFR4x4 | |
Alarm output cable | CEFR2x0.75 or CEFR10x0.75 | ||||||
Power supply | 3φ-380V/50Hz or 3φ-440V/60Hz | ||||||
Separator unit model parameters | |||||||
Model | DS(A)204-S(O) | DS(A)405-S(O) | SS(A)203-E | SS(A)204-E | DS(A)203-E | DS(A)204-E | |
Item | |||||||
Separated volume | Rated value | 2000 | 3000 | 1500 | 2000 | 1500 | 2000 |
(L/H) | 0# Diesel oil | 2200 | 3500 | 1600 | 2200 | 1600 | 2200 |
30# SAE LO. | 1200 | 1800 | 800 | 1200 | 800 | 1200 | |
180Cst/50℃HFO | 1100 | 1600 | 700 | 1100 | 700 | 1100 | |
Power(KW) | Separator | 3 x2 | 5.5 x2 | 1.5 | 3 | 1.5x2 | 3 x2 |
Oil feed pump | 1.5(1.5x2) | 1.5(1.5x2) | 1.5 | 1.5 | 1.5(1.5x2) | 1.5(1.5x2) | |
E-heating | / | / | 3x3 | 6x3 | 5x3(5x3x2) | 8x3(8x3x2) | |
Others | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | |
Slag discharge way | Auto slge / Auto partial discharge | ||||||
Heating way | Steam 0.45~0.7MPa /Conduction oil 170~210℃ | By electricity | |||||
Control way | Relay/by PLC auto control | ||||||
Machine weight | 1390 | 1715 | 800 | 835 | 1550 | 1620 | |
Outline dimension(mm) | Length | 2000(2200) | 2200 | 1150 | 1150 | 2200 | 2200 |
Width | 1200 | 1250 | 1150 | 1150 | 1200 | 1200 | |
Height | 1700 | 1780 | 1700 | 1700 | 1700 | 1700 | |
Interface dimension | Fuel oil inlet/ | DN32/ | DN40/ | DN25/ | DN25/ | DN25/ | DN32/ |
outlet/ | DN32/ | DN40/ | DN20/ | DN25/ | DN25/ | DN32/ DN32 | |
return oil outlet | DN32 | DN40 | DN20 | DN25 | DN25 | ||
Medium inlet | DN20(DN25) | DN25 | / | / | / | / | |
Medium outlet | DN20(DN25) | DN20(DN25) | / | / | / | / | |
Control water inlet | G1/2” | G1/2” | G1/2” | G1/2” | G1/2” | G1/2” | |
Incoming cable | CEFR4x4 | CEFR4x6 | CEFR4x6 | CEFR4x10 | CEFR4x16 | CEFR4x25 | |
Alarm output cable | CEFR2x0.75 or CEFR10x0.76 | ||||||
Power supply | 3φ-380V/50Hz or 3φ-440V/61Hz | ||||||
Oil Separator unit Parameter Table | ||||||
Model | KYDR203CD-21 | KYDB203DD-21 | KYDB204DD-21 | KYDB405SD-21 | KYDB309SD-21 | KYDB513SD-21 |
Item | ||||||
Rated Separater Volume | 2000 | 1500 | 2000 | 3000 | 6000 | 10000 |
Drum Rotating Speed (r/min) | 9000 | 9400 | 9300 | 9100 | 5800 | 6200 |
Separating Factors(g) | 12450 | 9037 | 9910 | 12034 | 7050 | 9131 |
Engine Power(Kw) | 2.2 | 1.5 | 3 | 5.5 | 11 | 15 |
Drive Way | High-speed Strap | |||||
Start/Stop time | 3~5min/10~15min | 5~8 min/15~20min | ||||
Sludge Discharge Way | Manual Discharge | Auto Valve-circled Partial Discharge | ||||
Dirty Oil Input Way | Independent External Pump | |||||
Dirty Oil Input Pressure | ~ 0.1 | |||||
Purified Oil Output Way | Concentric Pump | |||||
Purified Oil output Pressure (MPa) | 0.2-0.3 | |||||
Controlled-water Pre./Tem.(MPa)/(℃) | 0.02~0.7 (No requirement) | 0.2-0.3 / 85-95 | ||||
Net Weight (Kg) | 268 | 250 | 270 | 400 | 900 | 1100 |
Outline Dimension | 720x450x850 | 710x420x840 | 720x450x850 | 840x510x930 | 1220x800x1300 | 1300x900x1450 |
Power Supply (V/Hz) | 3ф-380V/50Hz, 3ф-440V/60Hz |
![]() |